- Home
- ยป
- Our Products
- »
- Endo-Mechanical Devices
Endo-Mechanical Devices
MIRUS Powered Endoscopic Linear Cutter and Reloads
Minimum Order Quantity: 1 Piece
Product Brochure
| Length | 60 mm |
| Rows of staples | 3 rows |
| Staple height | 3.5 mm |
| Use type | Reusable handle |
| Action | Cutting stapler |
| Staple material | Titanium |
| Reload color | White |
| Packaging | Individual pack |
Highlights
- Battery Motivated Endoscopic Linear cutter Cuts and Staples with three Staggered Rows
- Innovative and Consistent Staple Formation
- 60 degree articulation provides better access to narrow spaces
- Battery Motivated Endoscopic Linear cutter with Stability and Control
- Non-slip Anvil for better Compression
- Safety switch for secure surgery
- 3 rows stair stepping technology for superior hemostasis
- Cartridge remover for ease of use
Additional Information:
- Delivery Time: 3
Meril MIRUS Disposable Skin Stapler
Product Brochure
| Minimum Order Quantity | 1 Piece |
| Staples per stapler | 35 staples |
| Use type | Disposable |
| Staple width | 7.0 mm |
| Application area | General surgery |
| Sterility | EO sterile |
| Handle design | Plastic body |
| Packaging | Individual pack |
Wound closure is final step of surgical procedure. Wound closure involves the closing of Skin at the end of surgical intervention. Wound length may vary according to the surgery. There are three main layers of the skin.
Epidermis is the top layer of the skin, the part of the skin you see. Dermis is the second layer of skin. It's much thicker and does a lot for your body. Subcutaneous fat is the bottom layer.
Highlights
- The angled head.
- 316 L stainless steel pins with sharp cut edges.
- Centre Mark for alignment.
- 35 wide pins with transparent housing.
- Hard blister packaging.
Advantages
• Saves Time for wound closure.
• Easy to use for nurses and doctors.
• Lesser Trauma to the patients.
• Easy extraction of Staple pins from patients.
• Better cosmetic effect.
Additional Information:
- Delivery Time: 3
Meril MIRUS Skin Staple Remover
Product Brochure
| Minimum Order Quantity | 1 Piece |
| Type | Disposable |
| No. of uses | Single use |
| Operation | Manual |
| Sterility | Sterile |
| Packaging | Box pack |
Indication
Application in multiple open or minimally invasive General Surgery, Gynaecologic, Gastrointestinal, Oncology, urology, Thoracic, and Paediatric surgical procedures for transection, resection and creation of anastomosis
Highlights
- Battery Motivated Endoscopic Linear cutter Cuts and Staples with three Staggered Rows
- Innovative and Consistent Staple Formation
- 60 degree articulation provides better access to narrow spaces
- Battery Motivated Endoscopic Linear cutter with Stability and Control
- Non-slip Anvil for better Compression
- Safety switch for secure surgery
- 3 rows stair stepping technology for superior hemostasis
- Cartridge remover for ease of use
- Cuts and staples tissue simultaneously. Offers two double staggered rows of titanium staple on each side of the cutline.
- Push button opening & rear hinge alignment.
- New knife with every reload.
- Uniform Compression & Consistent staple formation gives superior hemostasis.
- Ease of handling facilitates better tissue manipulation.
- A new Knife gives precise and smooth transection.
- Aids better transection, resection and creation of anastomosis.
Highlights
- Strong, low profile anvil & long slim shaft
- One hand operation to close, fire and release
- Parallel jaw closure
- Provides optimum access without deflection.
- Ergonomic single hand operation design for ease of use.
- Consistent staple formation and superior hemostasis.
- Better pre-firing tissue manipulation with tissue retaining pin & Intermediate locking mechanism.
Advantages
- Linear stapler is Mechanical stapler that cannot cut but it staples the tissues.
- Its is available in 30mm, 45mm, 60mm, & 90mm sizes with two different staple sizes of cartridges.
- This Mechanical stapler has staple length of 3.5mm (blue color cartridge for standard tissues) & 4.8mm (green color cartridge for thick tissues).
- Cartridge has 2 staggered rows of titanium staples.
- MIRUS Linear Stapler can be fired maximum up to 10 times and is a single patient use device.
- Release button is provided for easy opening.
- Cartridge has tissue retaining pin which helps in alignment of anvil & cartridge.
- Only same size linear stapler cartridges can be fixed in same size linear stapler gun.
Highlights
- Optimum stapler housing capacity (14cc).
- Three circular staggered rows of staple pins (48 titanium staple pins).
Treatment for Hemorrhoids (Piles) Surgery
Piles, clinically known as Hemorrhoids, is the swelling of the blood vessels near the anal opening. An increased pressure on these blood vessels due to any reason, causes them to enlarge and swell, thus forming lumps which are occasionally felt at the anal opening. Hemorrhoidectomy is a surgery to remove internal or external hemorrhoids that are extensive or severe
Highlights
- Revolutionary III Row staple line.
- Stainless steel anvil shaft with longer purse tying area.
- Wing nut & staple compression gauge with adjustable staple height.
Advantages
- It offers the best in class "B" shape staple formation & cutting with precision which ensures better security and superior hemostasis.
- MIRUS Circular Staplers have application throughout the alimentary tract for end-to-end & end-to-side anastomosis.
- II rows for secure heamostasis & III rows for better security & superior hemostasis.
- Sizes available : 2 row: 24,25,26,29,32
- 3 row: 21,24, 25, 26, 29, 31,32
Additional Information
Available in II and III Rows model MIRUS
It has stainless steel anvil shaft with longer purse tying area.
Tissue compression gauge (Staple compression gauge) is provided to ensure the accurate staple formation & which suits to variable tissue thickness.
Wing nut like shape of rotating knob is provided for proper rotation and dexterity while opening and closing anvil.
The audible & tactile feedback (clicking sound) is better as compared to others.
Mirus Circular Stapler – Instrument
Disease Area: Rectum
Procedure Steps:
Access through separation of GI layers
Identification and mobilization of malignant area
Transection, Resection & Anastomosis
Open Mirus circular stapler with the help of black rotating knob available at the proximal end and disengage the anvil to expose the trocar & then close it. Ensures that trocar goes completely inside the housing during closing. Take anvil & purse string at proximal end of lumen and ensure that it should be tight properly.
Insert the circular stapler in anal canal & ensures that it reaches to the closed end of distal lumen. Then again open the circular stapler with the help of black rotating knob. Ensures that circular stapler advancing the trocar & pierce above & below the staple line of rectum. It should not go through the staple line. Then fully advance the trocar with the help of rotating knob.
Ensures that the orange indicator is visible inside the abdominal cavity & outside the staple line. Rotate the knob & close circular stapler slowly till rotation motion is halted. Observe the tissue compression indicator available on the top of circular stapler. Red marking should be in or below green zone (only then you will be able to open the red safety).
Wait for 30 secs so that the tissue will extrude out & tissue becomes dry. Open red safety lock. Now fire the circular stapler with 2 hands on a single fluid motion. Full squeeze is compulsory (100% squeeze). Release the handle & engage red safety back to original position. Open the instrument by turning the Wing Nut counterclockwise as indicated on the end of the knob. For easy removal, only open the instrument one-half to three-quarters revolutions. Remove circular stapler from anal canal with fish tale movement. Check the 2 donuts (both proximal & distal side).
Instrument Use:
- To Close inner organs before transection.
- To close the common opening or enterotomy after creating a anastomosis.
- To Make side to side or functional end to end anastomosis.
- Biopsy or wedge resection of the lung and dosing of the bronchus and to close.
- Prior to division, the pulmonary vessels.
- Resection of solid organs such as Liver or Pancreas.
Treatment
A colectomy is surgery to remove all or part of the colon. Nearby lymph nodes are also removed.
Highlights
- Minimaly invasive and faster surgeries.
- Minimal bleeding.
- Less postoperative pain.
- Short recovery time.
- Low risk of complications.
- Lesser damage to surrounding tissue.
- Local Anesthesia.
- Precise Ablation and Coagulation.
- Optical entry - 10mm, 12mm and 15mm
- Birdwing bladeless tip
- Primary seal
- Secondary seal
- Optical entry enables visualization of tissue layers during insertion and makes the entry safe
- Optical Entry Options: Birdwing Tip bladeless design separates tissue rather than cutting it, results in low port site herniation
- Primary seal accommodates wide range of Instrument sizes
- Secondary seal facilitates specimen retrieval, Hernia mesh introduction and Laparoscopic suturing
- Sizes in 5 mm, 10 mm and 12 mm
- Bladeless tip separates tissue rather than cutting it, results in low port site herniation
- Primary seal accommodates wide range of instrument sizes
- Secondary seal facilitates specimen retrieval, hernia mesh introduction and laparoscopic suturing
- Patient Safety: The device operates without electrical current passing through the patient's body, preventing neuromuscular stimulation and focusing energy at the instrument tip to minimize collateral tissue damage.
- Operational Efficiency: Combines cutting and coagulation in a single instrument, enabling precise dissection and efficient haemostatic sealing.
- Versatility: Suitable for a wide range of surgeries, including Upper Gastrointestinal, Colorectal, HPB, Bariatric, Gynecological, Urological, and Thoracic procedures.
- Ergonomic Design: Integrated tactile and auditory feedback guarantees precise and reliable performance.
- Enhanced Functionality: Supports cutting, grasping, and dissection with a single instrument.
The MIRUS™ Ligating Clips are widely used in surgery for vessel closure as well as for marking purposes. They are designed for use on tubular structures or blood vessels, wherever indicated.
- Lateral and transverse grooves
- Precise tip-to-tip closure
- Titanium clips
- 6 clips cartridge
- 12 appliers with different sizes and lengths
technology with an innovative design to deliver unparalleled performance in surgical
settings. This compact system redefines operational efficiency with its all-in-one
design, eliminating the need for separate handpieces and footswitches