Micropoint qLabs Q1 Pro Electrometer PT-INR
Minimum Order Quantity: 1 Piece
Product Brochure
Automation Grade | Automatic |
Brand | Micropoint |
Model Name/Number | Q1 Pro |
Usage/Application | Laboratory |
Instrument Type | Electrometer PT-INR |
Sample Mode | Whole Blood |
Measuring Method | Micro Fluid |
Country of Origin | Made in India |
•10 μL of fingertip whole blood, fresh venous whole bloodor citrate whole blood
•On board quality control
•External liquid QC (LQC) available
•Built-in temperature controlled testing
•Built-in barcode scanner
•No calibration or instrument manipulation required
Additional Information:
- Delivery Time: 6 Days
Jmitra Hiv Elisa Test Kit
Minimum Order Quantity: 1 Piece
Product Brochure
ICMR Approved | Yes |
Brand | Jmitra |
Sample Type | Blood |
Product Type | Elisa Kit |
Packaging Type | 96 Test |
Country of Origin | Made in India |
Microlisa HIV is an in-vitro qualitative enzyme immunoassay for the detection of antibodies to HIV-1 and /or HIV-2 in human serum or plasma. It is intended for screening of blood donors or other individuals at risk for HIV-1 and HIV-2 infection and for clinical diagnostic testing.
Salient Features- Use of Envelope Antigens gp41,C terminus of gp120 for HIV-1& gp36 for HIV-2.
- Detection of Group O & subtype C for HIV-1 prevalent in India.
- Color coded reagents to monitor procedural steps.
- Assay procedure: 90mins.
- Longer shelf life: 24 months at 2-8°C.
- Sensitivity & Specificity of 100% by WHO.
Microlisa HIV test is an enzyme immunoassay based on Indirect Elisa. HIV envelop proteins gp-41, C terminus of gp-120 for HIV-1 and gp-36 for HIV-2 representing Immunodominant epitopes are coated onto microtiter wells. Specimens and controls are added to the microtiter wells and incubated. Antibodies to HIV-1 and HIV-2 if present in the specimen, will bind to the specific antigens adsorbed onto the surface of the wells. The plate is then washed to remove unbound material. Horseradish peroxidase (HRPO) conjugated anti-human IgG is added to each well. This conjugate will bind to HIV antigen-antibody complex present. Finally substrate solution containing chromogen and hydrogen peroxide is added to the wells and incubated. A blue colour will develop in proportion to the amount of HIV-1 and / or HIV-2 antibodies present in the specimen. The colour reaction is stopped by stop solution. The enzyme substrate reaction is read by EIA reader for absorbance at a wavelength of 450 nm. If the sample does not contain HIV-1 or HIV-2 antibodies then enzyme conjugate will not bind and the solution in the wells will be either colorless or only a faint background colour develops.
Additional Information:
- Delivery Time: 1 Day
Jmitra Vitamin D Quanti Microlisa Elisa Test Kit 96 Test
Minimum Order Quantity: 1 Kit
Product Brochure
ICMR Approved | Yes |
Type | Quantitative ELISA |
Brand | J.mitra |
Usage/Application | Laboratory |
Sample Type | Blood |
Product Type | Elisa Kits |
Packaging Type | 96 Wells Plate |
Country of Origin | Made in India |
Vitamin D Quanti Microlisa is designed for in-vitro quantitative determination of vitamin D (total) in human serum.
Salient Features- Principle : Based on competitive immunoassay
- Quantitative detection of 25 –OH Vitamin-D2 & D3.
- Excellent sensitivity & specificity.
- Slandered are calibrated against international slandered reference NIST-SRM 972a.
- Linearity Range: 2.57 – 130 ng/ml.
- Analytical Sensitivity: 2.57 ng/ml
- Breakaway microwell strips.
- Color coded reagents to monitor procedural steps.
- Assay procedure: 90 mins.
- Prompt service back-up
- Long shelf life: 18 Months at 2-8°C.
- Convenient pack size: 96 tests.
Vitamin D Quanti Microlisa is an enzyme immuno assay based on delayed competitive ELISA. First samples are incubated with assay diluent to release vitamin-D from binding protein in the sample. Vitamin D biotin conjugate is added in the microwells.
During incubation endogenous 25-OH vitamin D of a sample competes with a 25-OH vitamin D3-biotin conjugate for binding of the anti-vitamin D antibodies immobilized on the plate (this delayed competition increases the sensitivity for low concentration vitamin-D samples). Incubation is followed by a washing step to remove unbound components. During a second incubation, binding of 25-OH vitamin D-Biotin is detected by enzyme conjugate (peroxidase labelled streptavidin). Washing is followed. In the third incubation color reaction is started by addition of substrate and stopped after a defined time. The color intensity is inversely proportional to the concentration of 25-OH vitamin D in the sample.
Additional Information:
- Delivery Time: 1 Day
Horiba Yumizen CA60 Semi Automatic Biochemistry Analyzer
Product Brochure
Type | Biochemical analyzers |
Automation | Semi Automatic |
Brand | Erba |
Assays | Clinical Chemistry |
Model Name/Number | HORIBA |
Reaction Cuvette | Flow Cell |
3ml BD Emerald Syringe
Minimum Order Quantity: 10 Box
Body Material | PVC Plastic |
Capacity | 3ml With Neddle |
Packaging Size | 100units |
Usage/Application | Hospital Clinical |
Brand | BD |
Packaging Type | Box |
Product Type | Syringe |
Country of Origin | Made in India |
5ml BD Emerald Syringe
Minimum Order Quantity: 50 Box
Body Material | PVC |
Capacity | 5ml |
Packaging Size | 100units |
Usage/Application | Hospitals |
Brand | BD |
Color | Transparent |
Gauge | 28g |
Packaging Type | Box |